With more than 45 years of experience, countless buildings across North America, and a growing portfolio of overseas projects, U-Build Steel Buildings are world-renowned for their quality and reliability. Through our sister company ARTSPAN Inc. we can offer insulated metal panels that are available in a variety of configurations, as seen below.
Summit panels are structural, self-framing panels that can reduce or eliminate the need for additional structural framework in your project. These panels can be used to form the floor, wall and roof systems of your building envelope.
THICKNESS | 5” |
EFFECTIVE R-VALUE* | 28.5 |
INTERIOR FACE 24ga deep corrugated galvanized G-90 (Z275) pre painted steel
* Thermal testing in accordance with ASTM C518.White White
Stone Grey
Charcoal
Buckskin
Dark Red
Heron Blue
Black
Frontier
Espresso
White White
Galvalume
Load Span Tables | Product: Structural Insulated Panel | Series: Summit |
Profile: Corrugated | Gauge: 26 ga or heavier | Finished: Embossed |
Standard | Description |
---|---|
CAN/ULC S101 |
Standard Methods of Fire Endurance Tests of Building Construction and Materials |
CAN/ULC S102 |
Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies |
CAN/ULC S126 |
Standard Method of Test for Fire Spread Under Roof-Deck Assemblies |
CAN/ULC S127 |
Standard Corner Wall Method of Test for Flammability Characteristics of Non-Melting Foam Plastic Building Materials |
CAN/ULC S138 |
Standard Method of Test for Fire Growth of Insulated Building Metal Panels in a Full-Scale Room Configuration |
ASTM E72 |
Standard Test Methods of Conducting Strength Tests of Panels for Building Construction |
ASTM E84 |
Standard Test Method for Surface Burning Characteristics of Building Materials |
ASTM E1646 |
Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems |
ASTM E1680 |
Standard Test Method for Rate of Air Leakage Through Exterior Metal Roof Panel Systems |
ASTM E283 |
Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen |
ASTM E331 |
Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference |
ASTM E1592 |
Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference |
ASTM C518 |
Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus |
ASTM C1363 |
Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus |
NFPA 286 |
Standard Methods of Fire Tests for Evaluating Contribution for Wall and Ceiling Interior Finish to Room Fire Growth |
Panel Orientation | Design Criteria | Allowable Loads (PSF) | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4' | 5' | 6' | 7' | 8' | 9' | 10' | 11' | 12' | 13' | 14' | 15' | 16' | 17' | ||
Flat Side Up | Bending / Shear | 500 | 400 | 300 | 220 | 169 | 133 | 108 | 89 | 75 | 64 | 55 | 48 | 42 | 37 |
Deflection (L/180) | 400 | 225 | 149 | 110 | 90 | 85 | 80 | 73 | 65 | 58 | 50 | 42 | 23 | 13 | |
Flat Side Down | Bending / Shear | 500 | 400 | 333 | 253 | 193 | 153 | 124 | 102 | 86 | 73 | 63 | 55 | 48 | 43 |
Deflection (L/180) | 400 | 225 | 150 | 110 | 90 | 85 | 80 | 73 | 65 | 58 | 50 | 42 | 23 | 13 |
TABLE NOTES: